Driscoil Equipment Logo
HomeEquipmentAbout UsContact Us
Inquiry Basket

Headquarters (Lagos)

5 Gbangbala street Lekki phase 1 opposite Prime Waters Estate, Lagos State, Nigeria

+234 (0) 8065576826
info@driscoil.com

Operational Base (Warri)

Enerhen Junction Industrial Layout, Warri, Delta State, Nigeria

+234 (0) 8137227843
info@driscoil.com

Operational Base (Port Harcourt)

Trans-Amadi Industrial Area, Port Harcourt, Rivers State, Nigeria

+234 (0) 7082654511
info@driscoil.com

Company

  • About Us
  • Blog
  • Contact

Categories

  • Drilling Equipment
  • Vessel/Tug Boat/Barges
  • Generators
  • Tank Cleaning Equipment

Legal

  • Privacy Policy
  • Terms of Use

© 2025 Driscoil Equipment Limited. All Rights Reserved.

Industrial Equipment Marketplace & Procurement

+234 8137227843
WhatsApp
info@driscoil.com
    1. Home
    2. Generators
    3. Load Banks
    Load Banks
    Available for Lease / RentPrice on Request / Contact for Quote

    Load Banks

    High reliability
    Environmental adaptability
    Industry standard compliant
    Available for immediate deployment
    Share:

    Quick Specifications

    Condition

    Verified

    Year

    2014

    Acquisition

    For Lease

    Availability

    Available

    Current Location

    Live

    Global Availability

    About the Product

    LOAD BANK Driscoil Equipment supplies industrial Load Banks for testing and commissioning diesel generators, gas generators, UPS systems, alternators, transformers, batteries and other electrical power systems. Load banks provide a controlled electrical load that allows operators to verify generator performance, capacity, voltage stability, frequency regulation and cooling-system performance without connecting the generator to its normal operating load. Technical Specifications Specification Typical / Available Configuration Equipment Type Electrical Load Bank Load Type Resistive / Reactive / Resistive-Reactive Testing Capacity From 10 kW to several MW Voltage Typically 230–690 V AC, model dependent Frequency 50 / 60 Hz Phase Single-phase / Three-phase Power Factor 1.0 for resistive; adjustable options for reactive systems Load Steps Typically 5%, 10%, 25%, 50% or custom Load Control Manual / Automatic / Digital Cooling Forced-air / Fan-cooled Control System PLC / Digital controller / HMI Connection Cable terminals / Camlock / Busbar Monitoring Voltage, current, frequency, kW, kVA, power factor Protection Over-temperature, overload, over-voltage and emergency shutdown Enclosure Indoor / Outdoor / Weatherproof Mobility Skid-mounted / Trailer-mounted / Containerized Remote Control Available on selected configurations Cooling Fans Electric motor driven Operating Temperature Model dependent Construction Heavy-duty industrial Applications Generator, UPS, transformer and electrical-system testing. LOAD BANK Driscoil Equipment offers industrial Load Banks for sale and lease, designed for controlled testing and commissioning of electrical power-generation and backup-power systems. Load banks simulate an electrical load without requiring the customer's normal facility load to be connected. This allows technicians to safely evaluate generator output, voltage regulation, frequency stability, engine performance, cooling performance and overall electrical-system reliability. Available in resistive, reactive and resistive-reactive configurations, with capacities ranging from smaller portable units to multi-megawatt industrial systems. For Sale & Lease | Portable & Trailer-Mounted | Resistive & Reactive | Generator Testing | UPS Testing | 50/60 Hz | Industrial & Oil & Gas Applications Driscoil Equipment Power Generation Equipment | Load Banks | Diesel Generators | Electrical Testing Equipment | Oil & Gas Equipment | Equipment Sales & Leasing | Equipment Mobilisation & Logistics

    LOAD BANK Driscoil Equipment supplies industrial Load Banks for testing and commissioning diesel generators, gas generators, UPS systems, alternators, transformers, batteries and other electrical power systems. Load banks provide a controlled electrical load that allows operators to verify generator performance, capacity, voltage stability, frequency regulation and cooling-system performance without connecting the generator to its normal operating load. Technical Specifications Specification Typical / Available Configuration Equipment Type Electrical Load Bank Load Type Resistive / Reactive / Resistive-Reactive Testing Capacity From 10 kW to several MW Voltage Typically 230–690 V AC, model dependent Frequency 50 / 60 Hz Phase Single-phase / Three-phase Power Factor 1.0 for resistive; adjustable options for reactive systems Load Steps Typically 5%, 10%, 25%, 50% or custom Load Control Manual / Automatic / Digital Cooling Forced-air / Fan-cooled Control System PLC / Digital controller / HMI Connection Cable terminals / Camlock / Busbar Monitoring Voltage, current, frequency, kW, kVA, power factor Protection Over-temperature, overload, over-voltage and emergency shutdown Enclosure Indoor / Outdoor / Weatherproof Mobility Skid-mounted / Trailer-mounted / Containerized Remote Control Available on selected configurations Cooling Fans Electric motor driven Operating Temperature Model dependent Construction Heavy-duty industrial Applications Generator, UPS, transformer and electrical-system testing. LOAD BANK Driscoil Equipment offers industrial Load Banks for sale and lease, designed for controlled testing and commissioning of electrical power-generation and backup-power systems. Load banks simulate an electrical load without requiring the customer's normal facility load to be connected. This allows technicians to safely evaluate generator output, voltage regulation, frequency stability, engine performance, cooling performance and overall electrical-system reliability. Available in resistive, reactive and resistive-reactive configurations, with capacities ranging from smaller portable units to multi-megawatt industrial systems. For Sale & Lease | Portable & Trailer-Mounted | Resistive & Reactive | Generator Testing | UPS Testing | 50/60 Hz | Industrial & Oil & Gas Applications Driscoil Equipment Power Generation Equipment | Load Banks | Diesel Generators | Electrical Testing Equipment | Oil & Gas Equipment | Equipment Sales & Leasing | Equipment Mobilisation & Logistics Designed for safe, efficient, and compliant operations.

    Configurable Options

    Standard configuration
    Custom modifications
    Data logging and monitoring
    Remote operation features

    Technical Specifications

    Similar Equipment You May Like

    Bucking Unit

    Bucking Unit

    Diesel Generator

    Diesel Generator

    Natural Gas Generator

    Natural Gas Generator

    Perkins Soundproof Generator

    Perkins Soundproof Generator

    Ayerbe Diesel Diesel Generator

    Ayerbe Diesel Diesel Generator